TX® (I) 150/250V 37P1.5

Description

Description

Standards

  • Product
    IEC 60228
  • Installation
    IEC 60092-350; IEC 60092-360; IEC 60092-376
  • Test
    IEC 60332-1; IEC 60332-3-22; IEC 60754-1; IEC 61034

 

Application

TX® (I) 150/250 V  overall and individually screened twisted pair cables are used for telecommunication and instrumentation purposes. These cables show strong protection aganist cross-talk and result into a good compromise between TX®(C) and TCX®(C)  cables against external electromagnetic disturbances. Designed with halogen-free fire retardant materials, they provide optimum safety for people and maximal asset protection against all risks of fire.

Design

  1. Conductor
    Stranded bare copper class 2
     
  2. Insulation
    XLPE (Cross-linked polyethylene
     
  3. Individual screen
    Alu/polyester tape with a tinned copper drain wire
     
  4. Outer sheath:
    Polyolefin SHF1 (SHF2 on request)
    Colour : grey
     

Marking

NEXANS 279 TX(I) Nber of pairs/triads & cross-section 150/250V 90C IEC 60092-376 IEC 60332-3-22 Cat.A WW YYYY *CE* Manufacturing n° + metric marking

Core identification

Pair: white / blue with printed pair number
Triad: white / blue / red with printed triad number

Characteristics

Characteristics

구조적 특성

구조적 특성

Conductor flexibility
트위스팅 레벨 2
Halogen free
IEC 60754-1
도체 재료
베어 구리 와이어
절연
XLPE (Cross-linked Polyethylene)
Individual screen
Aluminium / Polyester tape
Drain wire
주석 도금 구리
피복
폴리올레핀
Sheath colour
회색

치수

치수

Nominal outer diameter
36.1 mm
Number of pairs
37
Number of triples
-
도체 단면적
1.5 mm²
Minimum outer diameter
35.0 mm
Maximum outer diameter
38.5 mm
무게(근사치)
2010 kg/km

전기적 특성

전기적 특성

정격전압 Uo/U (Um)
150 / 250 (300) V
20° C에서 최대 도체 DC저항
25.6 Ohm/km

사용 특성

사용 특성

Fire retardant
EN IEC 60332-3-22 (cat A)
난연
IEC 60332-1
Gases corrosivity
IEC 60754-2
연기밀도
IEC 61034
Electro magnetic interference resistance
Yes
Max. conductor temperature in service
90 °C
操作温度范围
-30 ... 80 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close